Objective
Each Objective has a specific set of inputs available, based on the Objective Scope selected.
Objective Scope
In each study, the wall system is divided into non-equidistant cells, from the external material to the internal material. Speckel will generate no more than 10 cells per material with widths that are thinner near the boundaries of each material where most changes are expected and detail is needed.
Entire Construction
Cells are assessed across the entire construction.
By Material Type
Cells are assessed across the nominated material types.
By Material Index
Cells are assessed across he nominated material indices.
By Material Sensitivity
Cells are assessed across he nominated material sensitivities.
External Material
Cells are assessed in the external material.
Internal Material
Cells are assessed in the internal material.
Materials
Choose which Materials are included for analysis. Only applicable to 'By Material Type' assessments.
Sensitivities
Choose which Sensitivities are included for analysis. Only applicable to 'By Material Sensitivity' assessments.
Target
Set the target Min or Max of the Objective.
Max Target
Set the target value of the Objective.
Region Grouping
Nominate how Regions of analysis are created for your objective. For example, Insulation is often analysed within 10 mm of the material.
All Cells in Construction
Set Objective for all cells across the entire construction.
All Cells in Material
Set Objective for all cells in all materials.
Min Depth into Material
Set Objective as a minimum depth into all materials.
Max Depth into Material
Set Objective as a maximum depth into all materials.
Max External Depth into Material
Set Objective as a maximum depth into external material.
Max Internal Depth into Material
Set Objective as a maximum depth into internal material.
External Cell of Material
Set Objective for the outer cell of the external material.
Internal Cell of Material
Set Objective for the inner cell of the internal material.
All Cells Combined
Set Objective for all cells of all materials combined.
Min Depth
Set the minimum depth for the Objective region.
Max Depth
Set the maximum depth for the Objective region.
Min Hours
Set the minimum percentage of hours that the Objective must achieve.
Custom Outputs
Title
Add specific title to the Objective.
Text – before
Add custom text before Objective decision.
Text – After
Add custom text after Objective decision.
Show Result
Show the result decision visible immediately after simulation completes.
Show Report
Show the detailed report visible when selecting "View Summary”.
PDF Summary Results
Include a summary report at the start of the PDF document.
PDF Detailed Results
Include a detailed report at the end of the PDF document.