NCC 2022 Condensation Management Requirements

The issue of condensation within buildings has long been a concern for architects, engineers, and occupants alike. Excessive internal moisture can lead to a myriad of problems, ranging from mould growth and structural damage to health risks for the building's occupants.

Part F8 Condensation Management of the National Construction Code (NCC) 2022, has been developed to address this critical challenge to reduce the risk of illness or loss of amenities caused by condensation within buildings.

This article explores the National Construction Code (NCC) 2022 objectives, functional statements, performance requirements, and verification methods outlined in Part F8.

F801 Objectives

At the heart of Part F8 Condensation Management lies the primary objective of safeguarding occupants from potential health hazards or discomfort due to excessive internal moisture. This overarching goal serves as a guiding principle for developing and implementing condensation management strategies within buildings. By prioritising occupant well-being, Part F8 sets a high standard for construction practices that mitigate the adverse effects of condensation.

F8F1 Functional Statements

To safeguard occupants, F8F1 emphasises the need for buildings to be constructed to prevent the accumulation of excessive internal moisture within their structure. This functional statement highlights the importance of thoughtful design, proper insulation, and effective ventilation to control humidity levels and minimise the risk of condensation-related issues.

F8P1 Performance Requirements

F8P1 states the following:

Risks associated with water vapour and condensation must be managed to minimise their impact on the health of occupants.

F8P1 strongly emphasises managing water vapour and condensation effectively to minimise their impact on occupants' health. By enforcing performance requirements, the code compels builders and designers to adopt best practices in moisture control, thus mitigating the risk of mould growth and other health hazards associated with excessive humidity.

F8V1 Condensation Management

A comprehensive verification method is provided within F8V1 to ensure adherence to the performance requirements.

(1) Compliance with Performance Requirement F8P1 is verified for a roof or external wall assembly when it is determined that a mould index of greater than 3, as defined by Section 6 of AIRAH DA07, does not occur on—

  1. the interior surface of the water control layer; or

  2. the surfaces of building fabric components interior to the water control layer.

(2) The calculation method for (1) must use—

  1. input assumptions in accordance with AIRAH DA07; and

  2. the intermediate method for calculating indoor design humidity in Section 4.3.2 of AIRAH DA07.

This verification method involves assessing the mould index on part of a roof or external wall assemblies to ascertain that a mould index of greater than three is not achieved. Section 6 of DA07 Criteria for Moisture Control Design Analysis in Buildings provides the moisture performance evaluation criteria (the mould growth index), while Section 4.3.2 determines the intermediate method. The use of AIRAH DA07 criteria for determining the mould index and indoor design humidity ensures a rigorous and reliable assessment of condensation risks.

Last updated