LogoLogo
🎚️ UpdatesπŸ‘‹πŸ½ Book a Demo🎫 Get SupportπŸ–ŠοΈ Sign-up
  • πŸ‘‹Basics
    • Welcome
    • Get Started
      • Sign-up
        • Single Sign-On (SSO)
      • Create a Team
      • Create a Project
      • Create a Design
      • Grab a 7-day Trial
      • Plans
        • Community Plan
        • Essentials Plan
        • Practice Plan
        • Enterprise Plan
        • Education Plan
        • Suppliers Plan
        • Credits
        • Offers
          • Sculptform Offer
          • PHINZ Offer
        • Plans 2025 - Starting 1 July 2025
    • Get Support
      • Applications
        • Building
        • Wall
        • Floors and Subfloors
        • Roof
      • Support Tickets
      • On-demand Courses
        • Geometry
        • H1 AS1 & VM1
        • NCC 2022: J1V3
        • Moisture
        • Themes
        • Daylight
        • DTS FaΓ§ade Calcs
        • Total R-values
        • NCC 2022: J1V5
        • Part J4 Building Fabric
        • 3D Geometry in SketchUp
        • H1 VM2
        • BESS: Daylight Access
        • DQLS: Daylight Modelling
        • HVAC Sizing
        • Dew Point
        • Green Star: Daylight
        • CIBSE TM59
        • G7 Natural Light
        • Advanced Shading
        • IDF Exports and Imports
        • 2D to 3D Specification
      • Project Support
      • Testing and Verification
        • EnergyPlusβ„’ V 9.5.0 + 22.2
          • Input Output Reference
          • Engineering Reference
          • ANSI/ASHRAE Standard 140
        • Radiance V 5.2
        • Total R-value Calculations (AS/NZ 4859.2 + NZS 4214)
        • System Total R-value Calculations (CIBSE Guide A)
      • Updates
      • FAQ's
        • Design & Specification
          • Acoustic
            • Sound Pressure, Frequency and Density
            • Weighted Sound Reduction Index Rw
            • Insulation and Density
            • Acoustic Glazing
          • Climate
            • AU Climate Zones
            • The Koppen Climate Classification System
            • NIWA Weather Files
          • Comfort
          • Complaince
            • Performance-Based Design Briefs
          • Materials
            • Control Layers
            • Material Definitions
            • Material Groups
            • Vapour Resistance
            • Surface Emissivity
            • Concrete in Construction
            • Efflorescence in Masonry
            • Glazing - Types
            • Glazing – Technology and Surface Treatments
            • Glazing - Low-E Coatings
            • Framing - Thermally Broken Frames
            • Emerging Technologies - Wall Products and Systems
            • Emerging Technologies - Glazing Products and Systems
            • Glazing - Safety and Defects
            • Pliable Membranes
            • Insulation - Open Cell
            • Insulation - Closed Cell
            • FaΓ§ade Systems
            • Rigid Air Barriers
        • Data And Security
        • Plans and Trials
        • Training and Workshops
        • Supplier Products
        • Billing
        • Other
  • πŸ“˜User Manual
    • Settings
      • Account Management
        • Upgrade Account
        • Update Payment Details
        • Update Profile
        • Add a Team Member
        • Delete A Team Member
        • Purchase Credits
        • Create a Theme
        • Cancel your Plan
      • Project Management
        • Copy a Project
        • Team Activity
        • Update A Project
        • Invite a Guest to a Project
        • Copy a Design to Another Project
        • Copy a Design
        • Delete a Design
        • Delete a Project
        • Delete a Team Member
        • Delete a Team
    • Wall, Roof and Floor
      • Materials
        • Select a Layout
        • Add a Material
        • Move a Material
        • Delete a Material
        • Change Material Properties
        • Adjust Insulation for Compression
        • Adjust an Air Cavity
        • Add A Thermal Break
        • Adjust Surface Emissivity
        • Add / Edit Framing
      • Module Settings
        • Total Height
        • Contact Resistance
        • Cavity Bridging
    • Building
      • Drawing
        • Import A Drawing Underlay
        • Edit Grid Settings
        • Hide Tags & Check Points
        • Flip Geometry
        • Calibrate A Drawing
        • Controlling Layers
        • Building Rotation
        • Set An Origin
        • Draw A Zone
        • Split A Zone
        • Locate Coordinates
        • Review Zones and Aspects
        • 3D View
        • Set A Zone Height
        • Define A Zones Purpose
        • Edit A Zone
        • Use Tagging
        • Duplicate Drawings
        • Matching Underlays
        • Filter Aspects
        • Filter Zones
      • Building
        • Levels
          • Add a Level
          • Duplicate a Level
          • Edit a Level
          • Add a Roof
          • Add a Daylight Grid
          • Add Shading
          • Specify a Roof
          • Add Roof Glazing
          • Add Custom Eaves
          • Project a Roof
          • Draw a Skylight
          • Specify a Skylight
        • Groups
        • Spaces
          • Create a Space
          • Update a Schedule
          • Update a Building Class
          • Add Occupants
          • Add Equipment Loads
          • Add Lighting Loads
          • Set Infiltration
          • Set Thermostats
          • Add HVAC
          • Set Sizing
        • HVAC
          • Add Plant HVAC
            • Air Handling Unit
              • Supply Air Fan
              • Return Air Fan
              • Outside Air System
              • Heating Coil
              • Cooling Coil
            • Chilled Water Loop
              • Chiller (Air Cooled)
              • Chiller (Water Cooled)
              • Four Pipe Heat Pump (Cooling)
            • Condenser Water Loop
              • Auxiliary Condenser Water Loop
              • Cooling Tower
            • Four Pipe Heat Pump
            • Hot Water Loop
              • Heating Device - Gas Boiler
              • Heating Device – Air Source Heat Pump
              • Heating Device – Four Pipe Heat Pump (Heating)
            • VRF Condenser Unit (Air Cooled)
            • Constant Air Volume System (Air Cooled)
            • Fan Coil Unit System (Air Cooled)
            • Variable Air Volume System (Air Cooled)
            • VRF Condenser Unit
          • Add Space HVAC
            • Air Terminal
              • Heating Coil
            • Fan Coil Unit
              • Cooling Coil
              • Heating Coil
              • Air Loop
            • Packaged Terminal Heat Pump (Split System)
              • Supply Air Fan
              • Heating Coil
              • Cooling Coil
            • VRF Terminal Unit
              • Air Loop
            • Constant Air Volume System (Air Cooled)
            • Fan Coil Unit System
            • Variable Air Volume System (Air Cooled)
            • Variable Refrigerant Flow
          • Select HVAC Templates
            • Fan Coil Unit - Air Cooled (EnergyPlus HVACTemplate)
            • Packaged Variable Air Volume (EnergyPlus HVACTemplate)
            • Packaged Constant Air Volume (EnergyPlus HVACTemplate)
            • Variable Refrigerant Flow (EnergyPlus HVACTemplate)
            • Central Plant and Air Handling System
            • Fan Coil Unit System (Electric Heating)
            • Fan Coil Unit System (Water Heating)
            • Four Pipe Heat Pump System
            • Variable Refrigerant Flow
            • Variable Refrigerant Flow (incl. Outside Air)
            • Water-cooled Package Unit
        • Shading
          • Add Extruded Form
          • Edit Shading
          • Surface Customisation
        • Renewables
          • Add Solar
          • Edit Solar
          • Add Renewable Energy
        • Modelling
          • Simulation
          • Site
          • Zones
          • Reporting
        • Reference Building
          • J1V3
          • V 2.6.2.2
          • H1 / VM1
      • Envelope
        • Walls
        • Roofs
        • Floors
        • Windows
        • Skylights
        • Glazed Doors
        • Opaque Doors
        • Shading
          • Add Local Shading
      • Building FAQ
        • Calculate Discharge Coefficients
        • J1V3 Reference Building - Control Thermostat
        • H1/VM1 - Infiltration and Ventilation
        • Accessing Designer Mode
        • Combining Zones
        • Adding a Skillion Roof or Sloping Ceiling
        • How do I model a Curtain Wall Spandrel?
        • Weather Data Sources
        • Create a Custom Location
    • Workflows
      • Energy Efficiency
        • H1/AS1
        • H1/AS2
        • H1/VM1
        • Part J4 Building fabric
          • J4D3 Thermal construction β€” general
          • J4D4 Roof and Ceiling Construction
          • J4D5 Roof Lights
          • J4D6 Walls and glazing
            • NCC 2019 FaΓ§ade Calculator and Speckel
            • Specification 37
          • J4D7 Floors
        • J1V3 Verification using a reference building
        • J1V5 Verification using a reference building for a Class 2 sole-occupancy unit
          • J1P2 Performance Requirements
          • J1P3 Performance Requirements
          • J1V5 HVAC Schedules
          • J1V5 Lighting Schedules
          • J1V5 Occupancy Schedules
          • J1V5 Cooking and Appliance Schedules
          • J1V5 Internal Heat Loads
          • J1V5 Air-conditioning Setpoints
          • J1V5 Natural Ventilation Requirements
        • V2.6.2.2 Verification using a reference building
          • V2.6.2.2 Method
          • Support Materials
        • Total R-values
        • Advanced HVAC
          • Zone Control Thermostat
          • EnergyPlus Sizing Calculations
          • Demand-controlled ventilation
          • Outdoor air reset-based controls
          • Modelling four-pipe heat pumps
          • Modelling a fixed minimum air flow rate on AHUs/VAVs
          • Customise fan performance curves
          • Customise chiller performance curves
          • Design Day Weather Overview
          • Modelling air source heat pumps
          • Green Star: Reference HVAC System Type 3
          • Advanced HVAC: Typical VAV System
          • Design Day Weather Overview
          • Customise chiller performance curves
          • Customise fan performance curves
          • Modelling a fixed minimum air flow rate on AHUs/VAVs
          • Modelling four-pipe heat pumps
          • Outdoor air reset-based controls
          • Demand-controlled ventilation
          • EnergyPlus Sizing Calculations
          • Zone Control Thermostat
          • Modelling air source heat pumps
        • Energy and Thermal FAQ's
          • Thermal Comfort - PMV
          • Thermal Comfort - CBE Model
          • Total R-value
          • Solar Control
          • VRF Modeling in EnergyPlus
          • Thermal Bridging - The Basics
          • Colour
      • Daylight
        • Grid
        • Surfaces
        • Simulation Settings
        • G7/VM1
        • Green Star
        • BESS
          • Daylight Access - Living Areas
          • Daylight Access - Bedrooms
          • Winter Sunlight
        • Daylight FAQ's
          • Metrics
          • Daylight Design - Introduction
          • Daylight Design - Glazing
      • Moisture
        • Scope
          • Objective
        • Model
        • Internal Conditions
        • External Conditions
        • Moisture FAQ's
          • Wind-driven Rain?
          • Hygrothermal Convergence Errors
          • Hygrothermal Weather Data Sources?
          • Hygrothermal Material Data
          • ASHRAE Fundamentals Cavity Ventilation
          • Mould Growth Index
          • NCC 2022 Condensation Management Requirements
          • Vapour Conversions
          • HAMT FAQ
          • Can I Model a Curtain Wall Spandrel with HAMT?
      • Dew Point
        • External Conditions
        • Internal Conditions
        • Layers
      • Carbon
        • Scope and Boundaries
        • Products (A1 - A3)
        • Construction (A4 - A5)
        • In-Use (B4)
        • End-of-Use (C2)
        • Carbon FAQ's
          • Embodied Energy - Introduction
          • System Boundaries (EN 15978)
          • Material Database
          • Upfront Carbon Emissions - Transport to Site (Module A4)
          • BRANZ COβ‚‚NSTRUCT (V2.0)
          • Database (Customised)
          • AusLCI (V1.38) Construction Carbon Emissions Factors V1Untitled
          • Life Cycle Assessment - Resources
      • Design Day
        • Settings
        • Design Day Reports
      • Designer Mode
        • Airflow Networks
          • Airflow Network Setup
          • Model Settings
          • Airflow Network Settings
            • Ventilation
          • Window Settings
          • Airflow Networks Definitions
        • CIBSE TM59
          • CIBSE TM59 Setup
  • ⏺️Recordings
    • Webinars
      • Specification 44
      • 3D Modelling
      • Part J4 Building Fabric
      • H1 Energy Efficiency: Design out Overheating with the Modelling Method
      • J1V5: The New Multi-Residential Compliance Pathway
      • NCC Shading Algorithms: Updates and Improvements
      • TM59: Design Methodology for Overheating Risk in Homes
      • Airflow Networks: J1V5, TM59 and Natural Ventilation
      • Moisture Management Updates
      • H1 Energy Efficiency Verification Methods
      • Designer Mode: Go Beyond Compliance
      • Community Plan Upgrade
      • Major Feature Release: Verification Method V2.6.2.2
      • H1 Compliance in 45 minutes: Buildings greater than 300 m2
      • H1 Compliance in 45 minutes: Housing and buildings up to 300 m2
      • Advanced HVAC Feature Overview
      • Designing for Embodied Carbon: Building for Climate Change
      • Designing for Natural Light: G7VM1 DQLS and HC5 Natural Light
      • Speckel 2.0 Release: From Compliance to Green Star
      • J1V5: A solution for flexible design or a race to the bottom?
      • NCC 2022: What's Coming This May
      • Advanced HVAC: Testing and Case Studies
      • Daylight Modelling: Planning to Rating Tools
      • Energy Plus 22.2.0: Testing and Verification
      • Life Cycle (Carbon) Assessments: Testing and Case Studies
      • H1 Energy Efficiency: From Schedule to Verification
      • H1 Energy Efficiency: Multi-unit Dwellings
    • Tutorials
      • Export Geometry from SketchUp/DesignPH into Speckel
      • New Spaces Release
      • Storey Height Update
      • 2D Selection Tool
      • Support Tickets
      • OpenStudio SketchUp Plug-in
      • Pollination Rhino Plug-in
      • Add Clerestory Glazing to Your roof
      • Colour Scheme Hack
      • Daylight Results - An Overview
      • G7 Natural Light Verification Method G7/VM1
      • H1: Admin and Reporting
      • NCC 2022: Shading Multipliers
      • Materials: Create Your Own
      • Daylight / Natural Light Upgrade: G7, BESS & Green Star
      • BESS Daylight Access
      • G7 Grids: A Practical Example
      • Glazing: Multiple Windows Per Aspect
      • Wall Assessments: Thermal, Carbon
      • Roof Systems: Cold, Warm and Hybrid
      • Ceiling Heights: A Practical Example
      • Default Fabric: Setting Common Glazing
      • Drawing Zones: Locking Against X and Y Axis
      • Tagging (Advanced): Create, Administer and Apply
      • Exports: Copy Tables, Images and Data
      • H1 Energy Efficiency - Multi-unit Dwellings
      • Tempered Zoning: Shifting the Thermal Line
      • Air Boundary: A Practical Example
      • External Doors: Residential + Commercial
  • 🀲Other
    • Platform Agreement
Powered by GitBook
On this page

Was this helpful?

  1. Basics
  2. Get Support
  3. On-demand Courses

Total R-values

PreviousDTS FaΓ§ade CalcsNextNCC 2022: J1V5

Last updated 5 months ago

Was this helpful?

This 16-minute course is part of a comprehensive series designed to guide professionals through the intricacies of thermal resistance modeling using Speckel. Focused on R-value calculations as outlined by standards such as AS/NZS 4859.2 and NZS 4214, this course explores the essentials of setting up wall systems, configuring material properties, and generating compliance reports. Participants will gain the knowledge and tools necessary to optimize building designs for energy efficiency.

Course Structure:

The course begins with an introduction to R-values and their significance in thermal performance assessments. Participants will learn about key standards, including AS/NZS 4859.2 and NZS 4214, and how these standards are applied in the modeling process. The session covers the basics of setting up a model in Speckel, including selecting supplier or generic templates and customizing wall systems layer by layer.

Next, the course delves into the practical aspects of configuring wall systems. Participants will explore how to build custom wall assemblies by adding various layers such as insulation, membranes, and framing. The course emphasizes understanding the impact of different materials, ventilated cavities, and thermal bridging on the overall R-value. Attendees will also learn to adjust parameters like framing spacing and contact resistance to refine the model.

The final segment covers running simulations and generating reports. This section highlights how to interpret R-value outputs, including the effects of summer and winter conditions, and how to align these with project requirements. Participants will learn to create detailed reports that summarize the R-value calculations, inputs, and assumptions, making them suitable for regulatory submissions and performance evaluations.

Key Learning Outcomes:

  • Understand and Apply R-Value Standards

  • Proficiently Set Up Wall Systems in Speckel

  • Run and Interpret Simulations

  • Produce Detailed Compliance Reports

Course Completion:

By the end of this course, participants will have a thorough understanding of R-value modeling and how to apply these calculations to optimize thermal performance in building designs. Participants who successfully complete the course and achieve an 80% pass mark on the final quiz will receive a Certificate of Completion. This course is ideal for professionals looking to enhance their expertise in thermal resistance assessments and ensure compliance with energy efficiency standards.

All courses are available in your Team. .

πŸ‘‹
Read more