Specification JVa Additional requirements
JVa has been reproduced without amendment, as per NCC 2019 - Vol 1 - Amendment 1.
1. Scope
This Specification contains requirements that must be complied with in addition to the modelling requirements of JV1, JV2 and JV3.
2. Additional requirements β general
In addition to the modelling requirements for JV1, JV2 and JV3, a building must comply withβ
(a) for general thermal construction, J1.2; and
(b) for floor edge insulation, J1.6(b) and J1.6(c); and
(c) for building sealing, JV4 or J3; and
(d) for deactivation, control and insulation of air-conditioning and mechanical ventilation systemsβ
(i) J5.2(a)(i); and
(ii) J5.2(a)(ii)(A); and
(iii) J5.2(a)(iv); and
(iv) J5.2(a)(vi); and
(v) J5.2(b); and
(vi) J5.2(c); and
(vii) J5.3(b); and
(viii) J5.3(d); and
(ix) J5.5; and
(x) J5.6; and
(xi) J5.8; and
(e) for testing package air-conditioning equipment not less than 65 kWr, AS/NZS 3823.1.2 at test condition T1; and
(f) for testing a refrigeration chiller, AHRI 551/591; and
(g) for interior artificial lighting and power control, J6.3; and
(h) for interior decorative and display lighting, J6.4; and
(i) for artificial lighting around the exterior of a building, J6.5; and
(j) for boiling water and chilled water storage units, J6.6; and
(k) for deactivation of swimming pool heating and pumping, J7.3(b)(ii) and J7.3(c); and
(l) for deactivation of spa pool heating and pumping, J7.4(b)(ii) and J7.4(c); and
(m) for facilities for energy monitoring, Part J8; and
(n) for deactivation of fixed outdoor space heating appliances, clause J5.9(c).
3. Additional requirements β NABERS Energy for Offices
Where not included in the building energy simulation to satisfy JV1(a), compliance must be achieved withβ
(a) for a tenant supplementary heating and cooling system, J5.7; and
(b) for carpark ventilation and lightingβ
(i) J5.3; and
(ii) J5.4; and
(iii) J6.2; and
(iv) J6.3; and
(c) for heating, cooling and ventilation equipment not covered by the NABERS Energy for Offices base building rating, Part J5; and
(d) for artificial lighting not covered by the NABERS Energy for Offices base building rating, Part J6.
4. Additional requirements β Green Star
Where not included in the building energy simulation to satisfy JV2(a), compliance must be achieved withβ
(a) for heating, cooling and ventilation equipment outside the scope of the Green Star model, Part J5; and
(b) for artificial lighting outside the scope of the Green Star model, Part J6.